0-16″wc thru 835’wc, PUR Cable Standard, Stainless Steel Sensor and Housing
The Model 59G General Purpose Level Transmitter is designed for level measurement in water and clean or waste fluids. Higher accuracy option is available to .10%. PVC and FEP cables are also available. 59G have the deepest level rating at 835′. A complete range of accessories for use in level applications are available, many from stock.
Features
IP-68 Rated
All Stainless Steel constructions
High Accuracy
RoHS Compliant
Pressure Applications
The Model 59G General Purpose Level Transmitter has a 1″ diameter 316L ss housing and sensor.
Polyurethane cable is standard.
Different cable materials and o rings are available.
Use it to measure Liquid Level and Depth for Water and Waste Water applications, Lift Stations, Reservoirs and Dams, Rivers, Holding Ponds, Wells, In-ground / Above Ground Tanks and with Inventory Tank Gauging.
Ranges from 0-40″WC thru 15 ‘WC have combined accuracy of +/- .50% FSO
Ranges greater than 15′ WC have combined accuracy of +/- .35% FSO
An improved accuracy on ranges <15’ is available at 0.10% FSO.
Viatran also offers a complete range of accessories for use in level applications such as a surge protector, cable hangers and weights, meters and junction boxes.
Pressure Ranges: 0-50, 100 Inches Water Column, 0-2, 3, 5 PSI
Combined Accuracy (Non-Linearity, Hysteresis, Repeatability): ≤±0.50% FSO for ranges < 15 Ft. W.C.
Compensated Temperature Range: 2° to 158° F (0 to 70° C)
Operating Temperature Range: 14° to 158° F (-10 to 70° C) **Note: Medium must not freeze near sensor
Storage Temperature Range: -13° to 158° F (-25 to 70° C)
Long Term Stability (%FSO): ≤±0.1% FSO / year at reference conditions
Thermal Effect on Zero: ≤±0.8% FSO per 100° F
Thermal Effect on Span: ≤±0.8% FSO per 100° F
Output Signal: 4-20 mA
Supply Voltage: 8 -32 Vdc
Power Supply Regulation: <±005% FSO per volt
Circuit Protection: Reverse polarity protected, CE marked
RFI/EMI: CE EMC compliant as per IEC EN 61326
Voltage Spike Protection: Withstand 1000 volt spike per EN 61000
Response Time: <10mSec
Pressure Connection: Protective POM cap
Ingress Protection: IP 68
Overpressure Limit: 4x Minimum
Burst Pressure: 6x Minimum
Weight: 0.5 lbs. (without cable)
Housing: 316L stainless steel
Sensor Diaphragm: 316L stainless steel
O-ring Seals: FKM
Protective Cap: POM (Polyoxymethylene)
EA: Special Calibration Run
PW: Calibrate item with meter/display